Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.3807377

- Product Categories
- Swine artificial inseminati..
- Swine artificial inseminati..
- Canine artificial inseminat..
- Dipstick test card
- Pig related equipment
- Friendly Links
Product Name: | Detection of swine artificial insemination sperm density - 721 spectrophotometer |
Published: | 2011-03-18 |
Product Type: | Detection of swine artificial insemination sperm density - 721 spectrophotometer |
Product Description: | Specialized for sperm density, pig artificial insemination only. Out of traditional microscopy compute density. Spectrophotometer to be more precise, more accurate measurement of sperm density. Easy to use, more than 99% accuracy of data. This product is used in colorimetric analysis, the depth of color material solution color depends on the incident light intensity, the concentration of colored substances in solution, and liquid layer thickness. Solution when a bunch of monochromatic light, the incident light intensity and, the greater the concentration, the thicker the liquid layer, the solution absorbs more light, the relationship between them, in line with the quantitative law of light absorption material, namely, Lambert-Bear law. This is the spectrophotometric method for quantitative analysis of the theoretical basis for the material. Usage: 721 Spectrophotometer in the wavelength range 360 ??~ 800nm, the dispersion component for the triangular prism. 1. Inspection equipment starting position of the controls is correct, turn the power switch, open the sample chamber black-box lid, so that the meter pointer is "0" bit, warm 20min, and then select the required wavelength of monochromatic light used and the corresponding amplification of the sensitivity profile, with the tune "0" potentiometer to adjust the meter for the T = 0%. 2. Close the sample compartment lid by the photocell light, to promote the sample holder handle, so that pool of reference solution (a solution into the 4 / 5 height, set the first frame) in a light way, adjust the 100% transmission ratio regulator the meter pointer refers to T = 100%. 3. Repeat open the sample compartment lid, transfer 0,, covered with the sample compartment lid, and adjust the transmission ratio was 100% operation to the instrument stability. 4. Close the sample compartment lid, push handle the sample holder, placed in the sample solution pool of light on the road, read the absorbance values. Open immediately after reading the sample compartment lid. 5. Measurement is completed, remove the cuvette, washed and inverted on filter paper to dry. Original position of each knob, power switch to "off" and unplug. 6. Amplifier sensitivity of the file: "l" × 1 times; "2" × 10 times; "3" × 20 times, followed by increased sensitivity. Not the same as the wavelength monochromatic light, the light energy is different from the sensitivity of different files to be selected. Principle of selection is transferred to make the reference solution at T = 100%, try to use a lower sensitivity of the file, in order to improve the stability of the instrument. Change the sensitivity of documentation, should be re-tune "0" and "100." Specifications: Optical system: CT grating monochromator, 1200/mm Wavelength range: 360 ~ 1000nm Wavelength accuracy: ± 3nm Wavelength Repeatability: 2nm Measuring range :0-199 .0% T ,0-1 .999 A ,0-1999C Photometric accuracy: ± 1.0% T Photometric Repeatability: 0.5% T Spectral Bandwidth: 6nm Measurement of optical path: 100mm Stray light: ≤ 1.0% T (340nm Office) Stability: ≤ 0.004A / h (500nm preheated 1 hour) Display: 4 digit liquid crystal Basic measurements: T, A Data output (print): RS232C Source: 6V10W Operating voltage: 220V/110VAC ,50-60Hz Instrument Weight: 8kg Products: Behind the apparatus with RS232C Interface Color planes can be equipped with more than 100mm Application: This product is an economic analysis instruments, with RS232 output. Excellent photometric precision instruments higher than the same file. Widely used in medical testing, food, petrochemical industry, environmental protection and monitoring, and other fields. Specialized for sperm density, pig artificial insemination only. Out of traditional microscopy compute density. Spectrophotometer to be more precise, more accurate measurement of sperm density. Easy to use, more than 99% accuracy of data. South Korea imported semen 50g dilute short-acting powder South Korea imported semen 50g powder diluted long-term 100ml Korea imported semen diluent 20L --- semen refrigerator temperature of 17 degrees 50L --- 17 degree thermostat (standard models) 50L --- 17 degree incubator (enhanced section) 15L --- 17 degree thermostat, vehicle type |
Admin>>>
You are the 77527 visitor
Copyright © GuangDong ICP No. 10089450, Pastoral ORG Biotechnology Co., Ltd. Beijing All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 77527 visitor
Copyright © GuangDong ICP No. 10089450, Pastoral ORG Biotechnology Co., Ltd. Beijing All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility